“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta

“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
1 459,49 €
APC Metered Rack PDU is a three-phase, zeroU power distribution unit that measures and reports volts, amps, real power (kW) and energy (kWh). The unit includes an integrated LCD for local readout, supports remote real-time monitoring and historical reporting, and supplies power through an IEC 309 3P... Lue lisää
Varasto Loppu varastostaEi varastossa Tuotekoodi 124431 Merkki APC Malli AP8881 Takuu 2 vuotta

Toimitus ja palautukset

APC Metered Rack PDU is a three-phase, zeroU power distribution unit that measures and reports volts, amps, real power (kW) and energy (kWh). The unit includes an integrated LCD for local readout, supports remote real-time monitoring and historical reporting, and supplies power through an IEC 309 3P+N+PE input plug with a 1.8 m cord. Output is provided at 230 V via thirty-six C13 locking outlets and six C19 locking outlets. The PDU is compatible with EcoStruxure IT and supports daisy-chaining to monitor up to four PDUs from one IP address; it also offers SNMP, Web and Command Line Interface access and a local USB port for firmware updates.

Advantages

This meterable PDU actively measures, displays and logs electrical parameters to help prevent circuit overloads with user-defined alarms and real-time remote monitoring. Historical usage reports allow metering of customer power consumption, planning for capacity and optimizing energy use. The device operates reliably up to 60 °C, supports remote configuration and management, and includes Green Premium verification with a product environmental profile covering carbon footprint, scope 3 emissions and end-of-life instructions.

Key specifications

  • Type: Metered Rack PDU, zeroU, three-phase
  • Input: IEC 309 3P+N+PE plug, 1.8 m cord
  • Output voltage: 230 V
  • Outlets: 36 × C13 locking, 6 × C19 locking
  • Local display: LCD
  • Monitoring & management: EcoStruxure IT, Web, SNMP, CLI, USB local port
  • Remote monitoring: real-time monitoring, user-defined alarms, historical reporting
  • Environmental operating temperature: up to 60 °C
  • Daisy-chaining: supports monitoring up to 4 PDUs from one IP address
  • Sustainability: Green Premium product with verified environmental profile

How to use

Install the PDU in a rack using zeroU mounting and connect the IEC 309 3P+N+PE input plug to the appropriate three-phase supply. Configure network access via EcoStruxure IT, SNMP, Web interface or CLI and set user-defined alarms for overload protection. Use the LCD for local readings and the USB port for convenient firmware updates. For centralized monitoring, daisy-chain up to four PDUs and manage them from a single IP address.

Recommendations

Verify compatibility of the IEC 309 input with your facility power outlet and ensure proper circuit protection and grounding. Regularly review historical reports to optimize energy usage and plan capacity; apply firmware updates from the USB or network interface when available.

Tärkeimmät ominaisuudet
  • Type: Metered Rack PDU, zeroU, three-phase
  • Input: IEC 309 3P+N+PE plug, 1.8 m cord
  • Output voltage: 230 V
  • Outlets: 36 × C13 locking, 6 × C19 locking
  • Local display: LCD
  • Monitoring & management: EcoStruxure IT, Web, SNMP, CLI, USB local port
  • Remote monitoring: real-time monitoring, user-defined alarms, historical reporting
  • Environmental operating temperature: up to 60 °C
  • Daisy-chaining: supports monitoring up to 4 PDUs from one IP address
  • Sustainability: Green Premium product with verified environmental profile
Tekniset tiedot
AC-pistorasioiden määrä
42 AC outlet(s)
AC-tulotaajuus
50 - 60 Hz
Asennus
Vertical
Enimmäisteho
11000 W
Enimmäisvirta
16 A
Hiilijalanjälki yhteensä (kg CO2e)
41106.13
Kaapelin pituus
1.83 m
Kantavuus
11040 VA
Käytön suhteellinen ilmankosteus (H-H)
5 - 95%
Käyttölämpötila (T-T)
5 - 45 °C
Korkeus
1791 mm
Lähtöliitännät
36x IEC 320 C13 6x IEC 320 C19
Leveys
56 mm
Nimellislähtöjännite
230 V
Nimellistulojännite
400 V
Paino
6.38 kg
PDU-tyypit
Metered
Pistoke
IEC309
Pistorasiatyypit
C13 coupler, C19 coupler
Rack-kapasiteetti
0U
Säilytyksen suhteellinen ilmankosteus (H-H)
5 - 95%
Säilytyslämpötila (T-T)
-25 - 65 °C
Sertifiointi
CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Suurin kokonaisvirta vaihetta kohti
16 A
Suurin tulovirta vaihetta kohti
16 A
Syvyys
44 mm
Tuloliitännän tyyppi
IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
Tuotteen väri
Black
Valvonta
Current, Power, Voltage
Hintahistoria viimeisen 6 kuukauden ajalta
“APC AP8881” virranjakoyksikkö (PDU) 42 vaihtovirtaliitäntää 0U musta
Nykyinen
1 459,49 €
Alin
1 367,63 €
Ylin
1 591,99 €
Muutos 24 h
-132,49 €   -8%
Viikko
-23,69 €   -2%
Kuukausi
-58,80 €   -4%

Suositut tuotteet tässä kategoriassa

Myyjä: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilna, Liettua · Yritystunnus 303192950 · ALV-numero LT100008198612 · Toimitus EU:sta (Liettua)
Hei, olen DistriNoden tekoälyavustaja. Autan sinua löytämään tuotteita, vertailemaan vaihtoehtoja, laatimaan tarjouksia PDF-muodossa tai tekemään tukipyyntöjä.