APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa

APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
1 667,12 €
APC NetShelter Switched 0U Rack PDU delivers controlled power distribution for data centres and IT cabinets. This 0U, single‑phase PDU supports up to 5.0 kW at 200–208 V with a 30 A input (NEMA L6‑30P) and provides 24 AC outlets: 21 hybrid C13/C15 outlets and 3 hybrid C19/C21 outlets. The unit inclu... Lue lisää
Varasto Loppu varastostaEi varastossa Tuotekoodi 1723820 Merkki APC Malli APDU9941 Takuu 2 vuotta
KategoriaVirranjakoyksiköt (PDU)

Toimitus ja palautukset

APC NetShelter Switched 0U Rack PDU delivers controlled power distribution for data centres and IT cabinets. This 0U, single‑phase PDU supports up to 5.0 kW at 200–208 V with a 30 A input (NEMA L6‑30P) and provides 24 AC outlets: 21 hybrid C13/C15 outlets and 3 hybrid C19/C21 outlets. The unit includes a Network Management Card for remote monitoring and control, an interactive LCD for local measurements, a temperature/humidity sensor port and a USB port for local firmware updates. With compact 0U mounting and dimensions of 55×46×1829 mm, the PDU installs vertically without occupying usable rack units.

Advantages

The switched design enables outlet‑level on/off control and remote switching for power cycling, delayed power sequencing and outlet use management. Hybrid outlets accept standard C14/C20 cords and are rated to support higher temperature power cords, allowing compatibility with present and future server and network equipment. Integrated network management and secure interfaces support Web, SNMP and CLI access and simplify centralized monitoring and control. The PDU supports daisy‑chaining up to 32 units on a single IP address to reduce network complexity.

Suitable for

  • Rack power distribution in server rooms and data centres
  • Remote power cycling and management of individual servers and network devices
  • Environments requiring high‑density outlet provisioning and vertical 0U mounting
  • Integrations with monitoring platforms such as EcoStruxure IT

Key specifications

  • Output power capacity: up to 5.0 kW at 200–208 V
  • Input current: 30 A via NEMA L6‑30P plug (single‑phase)
  • Outlet count and types: 21 hybrid IEC 60320 C13/C15 and 3 hybrid IEC 60320 C19/C21
  • Mounting: 0U vertical rack installation; dimensions 55×46×1829 mm
  • Network management: onboard Network Management Card with Web, SNMP and CLI access
  • Local interface: color interactive LCD showing current, real power, voltage and energy
  • Sensors and ports: temperature/humidity sensor port and USB port for firmware updates
  • Security and standards: supports enhanced password policies and compliance with RoHS, CUL, FCC and PSE
  • Additional features: outlet locking when using locking cords, low‑profile circuit breakers, daisy‑chain up to 32 PDUs

How to use

Install the PDU vertically in a compatible rack using available 0U mounting points; connect the NEMA L6‑30P input plug to a properly rated branch circuit. Configure the Network Management Card via the Web interface, SNMP or CLI to assign IP addressing and security credentials. Use the color LCD for local measurements and status checks. Control individual outlets from the management interface for remote power on/off, sequencing or scheduled operations. Attach the temperature/humidity sensor where environmental monitoring is required and update firmware via the USB port as needed.

Recommendations

Verify rack airflow and device thermal ratings when populating high‑temperature equipment. Use compatible IEC power cords and locking cords where outlet locking is required. When daisy‑chaining multiple PDUs, plan IP addressing and network security settings to maintain visibility and control. Follow local electrical codes and work with qualified electricians for installation and service.

Tärkeimmät ominaisuudet
  • Rack power distribution in server rooms and data centres
  • Remote power cycling and management of individual servers and network devices
  • Environments requiring high‑density outlet provisioning and vertical 0U mounting
  • Integrations with monitoring platforms such as EcoStruxure IT
  • Output power capacity: up to 5.0 kW at 200–208 V
  • Input current: 30 A via NEMA L6‑30P plug (single‑phase)
  • Outlet count and types: 21 hybrid IEC 60320 C13/C15 and 3 hybrid IEC 60320 C19/C21
  • Mounting: 0U vertical rack installation; dimensions 55×46×1829 mm
  • Network management: onboard Network Management Card with Web, SNMP and CLI access
  • Local interface: color interactive LCD showing current, real power, voltage and energy
  • Sensors and ports: temperature/humidity sensor port and USB port for firmware updates
  • Security and standards: supports enhanced password policies and compliance with RoHS, CUL, FCC and PSE
  • Additional features: outlet locking when using locking cords, low‑profile circuit breakers, daisy‑chain up to 32 PDUs
Tekniset tiedot
AC-pistorasioiden määrä
24 AC outlet(s)
Asennus
Vertical
Enimmäisvirta
30 A
Ethernet LAN (RJ-45) -liitännät
1
Kantavuus
4992 VA
Käytön suhteellinen ilmankosteus (H-H)
5 - 95%
Käyttökorkeus
0 - 3048 m
Käyttölämpötila (T-T)
-5 - 60 °C
Käyttöopas
Yes
Kestävän kehityksen vaatimustenmukaisuus
Yes
Korkeus
1829 mm
Korkeus (ei käytössä)
0 - 15240 m
Leveys
55 mm
Nimellislähtöjännite
200 - 208 V
Nimellistulojännite
90 - 264 V
Paino
8.5 kg
Pakkauksen korkeus
2040 mm
Pakkauksen leveys
165 mm
Pakkauksen paino
10 kg
Pakkauksen syvyys
124 mm
PDU-tyypit
Switched
Pistoke
NEMA L6-30P
Pistorasiatyypit
C13 coupler, C15 coupler, C19 coupler, C21 coupler
Rack-kapasiteetti
0U
Säilytyslämpötila (T-T)
-25 - 65 °C
Sertifiointi
CUL , FCC 15 A, ICES-003, PSE
Syvyys
46 mm
Tuotteen väri
Black
Tyyppi
Single-phase
Vaatimustenmukaisuustodistukset
RoHS

Käyttöohje

Avaa asiakirja
Hintahistoria viimeisen 6 kuukauden ajalta
APC NetShelter Switched Rack PDU, 0U, 5,0kW, 200V ja 208V, 30A, 21 C13/C15 ja 3 C19/C21 pistorasiaa
Nykyinen
1 667,12 €
Alin
1 629,52 €
Ylin
1 792,01 €
Muutos 24 h
+4,19 €   +0%
Viikko
+8,07 €   +0%
Kuukausi
-24,75 €   -1%

Kirjoita arvostelu

Arvosana *
Nimesi näytetään julkisesti – voit käyttää nimimerkkiä. Kutsumme ostajia kirjoittamaan arvosteluja; tarkistamme arvostelut ennen julkaisua ja julkaisemme myös kriittiset.

Sama sarja ja vaihtoehdot

Suositut tuotteet tässä kategoriassa

Myyjä: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilna, Liettua · Yritystunnus 303192950 · ALV-numero LT100008198612 · Toimitus EU:sta (Liettua)
WhatsApp
Messenger
Hei, olen DistriNoden tekoälyavustaja. Autan sinua löytämään tuotteita, vertailemaan vaihtoehtoja, laatimaan tarjouksia PDF-muodossa tai tekemään tukipyyntöjä.
Kaikki kategoriat