Tili Ota yhteyttä
Ostoskorisi
Toimitus DPD & FedEx
Tarvitsetko apua? Kysy AI:lta

Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)

Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)
Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)
Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)
Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)
20,27 €
Cat.7 S/FTP network cable designed for operating frequencies up to 600 MHz, supporting Ethernet standards up to 10GBase-T. The cable uses fully braided shielding with additional foil shielding around each pair (S/FTP) and is individually packaged in a polybag. Gold-plated contacts and a snagless str... Lue lisää
Varasto 4 Tuotekoodi 1201550 Merkki LINDY Malli 47644 Takuu 2 vuotta

Toimitus ja palautukset

Arvioitu toimitusaika Tiistai, Lokakuu 27
Saat päivitykset yksityiskohtaisen seurantajärjestelmän kautta
Maksuvaihtoehdot
MaksukorttiVisaMastercardPayPalApple PayGoogle PayTilisiirto

Cat.7 S/FTP network cable designed for operating frequencies up to 600 MHz, supporting Ethernet standards up to 10GBase-T. The cable uses fully braided shielding with additional foil shielding around each pair (S/FTP) and is individually packaged in a polybag. Gold-plated contacts and a snagless strain relief protect the connector and ensure long-term, corrosion-free connections. Although Cat.7 originally specified GG45, this product uses RJ-45 connectors developed to meet Cat.7 performance; the cable marking may read "Cat.6A S/FTP patch cords with 600MHz raw cable".

Advantages

The S/FTP construction provides high protection against electromagnetic interference and crosstalk, enabling stable transmission at frequencies up to 600 MHz for networks up to 10GBase-T. Gold-plated contacts improve contact reliability and corrosion resistance, while the snagless strain relief reduces the risk of latch damage during installation and removal. Individual polybag packaging protects the cable during storage and transport.

Suitable for

  • Data centres and server rooms
  • Rack-mounted network and control cabinets
  • High-speed 10GBase-T networks
  • Patch panels and switch connections requiring S/FTP shielding
  • Home or office network installations where reduced interference is required

Key specifications

  • Standard: Cat.7 cable material (S/FTP) tested to ISO/IEC 11801
  • Bandwidth: up to 600 MHz
  • Transmission: up to 10GBase-T
  • Connectors: RJ-45 on both ends (nickel/gold plated contacts)
  • Shielding: braided overall shield plus foil around each pair (S/FTP)
  • Length (this product): 1.5 m
  • Colour: Green

How to use

Connect one RJ-45 plug to the network port of your switch, patch panel or device and the other to the corresponding port. Ensure connectors are fully inserted until the latch clicks to secure the connection. Route the cable to avoid tight bends and excessive tension; use cable management in racks or along walls to maintain bend radius and prevent strain on the connectors.

Recommendations

For optimum performance in 10GBase-T environments, use this S/FTP cable in shielded or grounded installations where possible and avoid running the cable in close parallel to high-power electrical lines to minimise interference.
Tärkeimmät ominaisuudet
  • Data centres and server rooms
  • Rack-mounted network and control cabinets
  • High-speed 10GBase-T networks
  • Patch panels and switch connections requiring S/FTP shielding
  • Home or office network installations where reduced interference is required
  • Standard: Cat.7 cable material (S/FTP) tested to ISO/IEC 11801
  • Bandwidth: up to 600 MHz
  • Transmission: up to 10GBase-T
  • Connectors: RJ-45 on both ends (nickel/gold plated contacts)
  • Shielding: braided overall shield plus foil around each pair (S/FTP)
  • Length (this product): 1.5 m
  • Colour: Green
Tekniset tiedot
AWG-johdinkoko
26
Johtimen materiaali
Copper
Kaapelin muoto
Round
Kaapelin pituus
1.5 m
Kaapelin suojaus
S/FTP (S-STP)
Kaapelistandardi
Cat7
Kaapelointitekniikka
10GBase-T
Käyttölämpötila (T-T)
-10 - 60 °C
Kestävän kehityksen vaatimustenmukaisuus
Yes
Korkeus
8.3 mm
Leveys
11.6 mm
Liitin 1
RJ-45
Liitin 2
RJ-45
Liittimen 1 mitat (LxSxK)
11.6 x 22.8 x 8.3 mm
Liittimen 1 muoto
Straight
Liittimen 1 uros/naaras
Male
Liittimen 2 mitat (LxSxK)
11.6 x 22.8 x 8.3 mm
Liittimen 2 muoto
Straight
Liittimen 2 uros/naaras
Male
Liittimen kontaktien pinnoitus
Nickel/Gold
Liittimen kotelon materiaali
Polycarbonate (PC)
Liittimen suojaus
Yes
Liittimen suojuksen materiaali
Aluminium
Määrä laatikkoa kohden
1 pc(s)
Määrä pakkauksessa
1 pc(s)
Pakkauksen tyyppi
Polybag
Plug and Play
Yes
Säilytyslämpötila (T-T)
-20 - 75 °C
Sertifiointi
RoHS, REACH, UL, California Proposition 65
Syvyys
22.8 mm
Taajuus
600 MHz
Taivutussäde (min.)
7.8 cm
Takertumaton kaapelinsuoja
Yes
Takuuaika
10 year(s)
Tuotteen väri
Green
Ulkohalkaisija
6.5 mm
Vaatimustenmukaisuustodistukset
REACH, RoHS
Vaipan materiaali
Low smoke zero halogen (LSZH)
Hintahistoria viimeisen 6 kuukauden ajalta
Lindy 47644 verkkokaapeli vihreä 1,5 m Cat7 S/FTP (S-STP)
Nykyinen
20,27 €
Alin
19,11 €
Ylin
25,83 €
Muutos 24 h
+1,04 €   +5%
Viikko
+0,99 €   +5%
Kuukausi
+1,05 €   +5%

Suositut tuotteet tässä kategoriassa

Hei, olen DistriNoden tekoälyavustaja. Autan sinua löytämään tuotteita, vertailemaan vaihtoehtoja, laatimaan tarjouksia PDF-muodossa tai tekemään tukipyyntöjä.