Tili Ota yhteyttä
Ostoskorisi
Toimitus DPD & FedEx
Tarvitsetko apua? Kysy AI:lta

Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m

Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
22,14 €
InLine fiber optic simplex cable LC/APC (8°) to SC/APC (8°) OS2 9/125µm, 30 m, is a single‑mode patch cable designed for FTTH installations and indoor/outdoor patching. The cable features OS2 9/125µm fiber with APC 8° polished terminations at both ends (LC to SC) and a 3.0 mm armoured construction w... Lue lisää
Varasto 90 Tuotekoodi 1429516 Merkki INLINE Malli 88430 Takuu 2 vuotta

Toimitus ja palautukset

Arvioitu toimitusaika Tiistai, Lokakuu 20
Saat päivitykset yksityiskohtaisen seurantajärjestelmän kautta
Maksuvaihtoehdot
MaksukorttiVisaMastercardPayPalApple PayGoogle PayTilisiirto

InLine fiber optic simplex cable LC/APC (8°) to SC/APC (8°) OS2 9/125µm, 30 m, is a single‑mode patch cable designed for FTTH installations and indoor/outdoor patching. The cable features OS2 9/125µm fiber with APC 8° polished terminations at both ends (LC to SC) and a 3.0 mm armoured construction with a low smoke zero halogen (LSZH) outer jacket. It is intended to link the house transfer point, ONT or modem, network equipment and fiber distribution panels where reliable angled APC connections and low insertion loss are required.

Advantages

The armoured 3.0 mm cable jacket and a stainless steel spiral tube provide mechanical protection and improved durability compared with thin pre‑installed cables. APC 8° polished connectors reduce back reflection and meet typical FTTH optical performance expectations with low insertion loss and high return loss. The white neutral sheath allows inconspicuous installation in living areas, and the LSZH material reduces hazardous emissions in case of fire. A test report for insertion loss and return loss is supplied to support quality verification.

Suitable for

  • Connecting FTTH terminal point to ONT or fiber modem
  • Patching between network equipment and fiber distribution panels
  • Indoor or protected outdoor routing where a slim, armoured single‑mode cable is required
  • Installations requiring APC angled terminations to minimise back reflections

Key specifications

  • Fiber type: OS2 single‑mode, 9/125 µm
  • Length: 30 m
  • Connectors: LC/APC (8°) male to SC/APC (8°) male
  • Connector polish: APC 8°
  • Cable outer diameter: approx. 3.0 mm ±0.2 mm (armoured)
  • Jacket material: Low Smoke Zero Halogen (LSZH), white
  • Armouring: flexible stainless steel spiral tube for mechanical reinforcement
  • Performance: typical insertion loss <0.20 dB, maximum insertion loss <0.30 dB, return loss >60 dB
  • Standards compliance: flame and emission standards listed for LSZH and fiber connector interfaces
  • Operational temperature range: -40 °C to +85 °C

How to use

Route the cable from the FTTH entry point or distribution panel to the ONT, modem or network device, avoiding tight bends and sharp edges. Insert the LC/APC connector into the corresponding LC/APC port and the SC/APC connector into the SC/APC port until the connectors click into place. Verify the orientation for APC connectors to ensure proper seating and minimal back reflection. After installation, check optical performance with available test equipment or review the supplied test report to confirm insertion loss and return loss meet expectations.

Recommendations

Avoid bending the cable below the manufacturer’s minimum bend radius, protect connector endfaces from dust with caps until final connection, and handle the armoured cable with care to prevent excessive deformation. Use a certified fiber cleaner and follow standard fiber safety practices when connecting or inspecting endfaces.

How to use

Route the cable from the FTTH entry point or distribution panel to the ONT, modem or network device, avoiding tight bends and sharp edges. Insert the LC/APC connector into the corresponding LC/APC port and the SC/APC connector into the SC/APC port until the connectors click into place. Verify the orientation for APC connectors to ensure proper seating and minimal back reflection. After installation, check optical performance with available test equipment or review the supplied test report to confirm insertion loss and return loss meet expectations.

Recommendations

Avoid bending the cable below the manufacturer’s minimum bend radius, protect connector endfaces from dust with caps until final connection, and handle the armoured cable with care to prevent excessive deformation. Use a certified fiber cleaner and follow standard fiber safety practices when connecting or inspecting endfaces.

Tärkeimmät ominaisuudet
  • Halogen free outer Jacket
  • Armoured Cable OD:3.0mm±0.2mm
  • flexible metal tubing one core
  • Fiber: OS2 9/125µm - single Mode
  • I-VH-2E,G.652.D
  • APC 8° Polished
  • IL<0.30dB,RL>60dB
  • IL(typical)<0.20dB
  • with test report
  • Conform IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +85°C
  • FTTH OS2
  • 30 m
  • LC Male
  • SC Male
  • Connector polish type: APC
  • Jacket material: Low smoke zero halogen (LSZH)
  • Single-mode
  • White
Tekniset tiedot
Full duplex
No
Hylsyn halkaisija
9 µm
Kaapelin halkaisija
3 mm
Kaapelin pituus
30 m
Kaapelin tyyppi
FTTH
Käyttölämpötila (T-T)
-40 - 85 °C
Kuidun moodirakenne
Single-mode
Kuitutyyppi
OS2
Liitin 1
LC
Liitin 2
SC
Liittimen 1 uros/naaras
Male
Liittimen 2 uros/naaras
Male
Liittimen hiontatyyppi
APC
Määrä pakkauksessa
1 pc(s)
Mitat (LxKxS)
10 x 30000 x 8 mm
Paino
377 g
Pakkauksen korkeus
28 mm
Pakkauksen leveys
235 mm
Pakkauksen paino
477 g
Pakkauksen syvyys
235 mm
Pakkauksen tilavuus
1600 cm³
Plug and Play
Yes
Säilytyslämpötila (T-T)
-40 - 85 °C
Sertifiointi
IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
Testipöytäkirja mukana
Yes
Tuotteen väri
White
Vaipan halkaisija
125 µm
Vaipan materiaali
Low smoke zero halogen (LSZH)
Hintahistoria viimeisen 6 kuukauden ajalta
Kuitu-simplexkaapeli InLine LC/APC (8°) - SC/APC (8°) OS2 9/125µm FTTH 30 m
Nykyinen
22,14 €
Alin
20,75 €
Ylin
27,52 €
Muutos 24 h
+0,92 €   +4%
Viikko
+0,96 €   +5%
Kuukausi
+1,00 €   +5%

Suositut tuotteet tässä kategoriassa

Hei, olen DistriNoden tekoälyavustaja. Autan sinua löytämään tuotteita, vertailemaan vaihtoehtoja, laatimaan tarjouksia PDF-muodossa tai tekemään tukipyyntöjä.